The MaxConcurrentExecutables is set by right-clicking the Control Flow and selecting properties.  The following are valid values for this property:

  • -1: Sets the maximum numbers of concurrently running executables to the number of processors, plus 2.
  • 1 or greater: The number of threads that a package can execute.

Any value of 0 or less, except -1, will result in an error.

What I missed wasn’t that it set the number of threads, rather, that -1 is equal to the number of processors plus 2.